| Preci Ball Castable Male Instructions |
|
|
![]() |
![]() |
|
| Female
|
Plastic Burnout Male
Pattern
|
Large Tin Spacer
|
|
| |
![]() |
||
| 1201 Mandrel | Activate/Deactivate Tool | 1201D Analogue |
Benefits:
Fabricating the coping
| 1 |
2 |
3 |
| The abutment is prepared for
either a post and coping (the Preci
Post system is recommended), or a cast coping only. Accurate full
arch impressions must be sent to the laboratory. Wax up the
post-coping as low as possible (FIG
1). Use
the 1201P Paralleling Mandrel
to incorporate the castable sphere into the wax-up and parallel to each
other(FIG 2).
The occlusal surface must be at an angle of 90 degrees
to the path of insertion (FIG
3).
|
||
4![]() |
5 |
| Invest, sprue, and cast in the alloy of choice (FIG 4). Do not sandblast the casting when devesting, as this will leave a rough surface on the cast sphere. Use the Cup Bur (FIG 5) to finish the cast sphere. This bur will assure a smooth, spherical shape of the casting. | |
Indirect pick-up of female
| 6 |
7 |
8 |
| The completed casting is sent out for try-in. The cast coping(s) should be picked up in a new impression and a new master model poured for processing the females. Take an impression with the male in place (FIG 6). The 1201D (FIG 7) analogue will index in the impression exactly where the male is in the mouth. Pour the model (FIG 8). | ||
Processing the Female
| 9 |
10 |
11 |
| The ball in place in the mouth, or on
a model (FIG 9). Place the large
tin spacer (FIG 10) over the ball and
contour the pliable tin spacer around the ball and gingival area (FIG
11) to pre-relieve the acrylic from contacting the cast coping.
Be sure to use the big tin
spacer.
|
| 12 |
13 |
| Seat the Preci Ball female over both the
ball and both spacers (shown in the mouth and model,
FIG 12 and FIG 13). Use the 1211
Female Paralleling Mandrel to assure that the females are parallel.
|
| 14 |
15 |
| Chairside: The prosthesis is relieved to allow room for the female component (FIG 14). Drill a "vent", or small channel in the lingual side of the prosthesis to allow excess acrylic to escape. Low viscous self-cure resin is applied (FIG 15) to pick up the female. |
| 16 |
17 |
| Chairside: The prosthesis is seated in the mouth for approximately 6 minutes with finger pressure only (FIG 16). Do NOT have the patient bite into place, as this will displace tissue. The self curing or auto polymerizing acrylic resin is pressed into the cavity with a finger covered with vaseline. When the acrylic resin has set, the metal housing is fixed in the prosthesis (FIG 17). This allows the female to be easily changed. |
T0041.REV.00