Locator
Component Listing

|
The Self-Aligning feature of the LOCATOR attachment allows a patient
to easily seat their overdenture without the need for accurate alignment of the
attachment components.
The unique Dual Retention innovation provides the LOCATOR attachment
with greater retention surface area than ever available before with other
attachments.
Durability tests have proven the LOCATOR's incredible wear resistance
and long lasting performance for over 110,000 insertion cycles.
The LOCATOR Male pivots in its permanent metal denture housing for a genuine
resilient connection of the prosthesis. The retentive nylon male remains in
static contact with the female socket while its metal denture cap has a full
range of rotational movement over the male. This design of the pivoting
LOCATOR Male allows a resilient connection for the overdenture without any
resulting loss of retention.
The LOCATOR attachment is a supra-radicular design that gives you the
choice of a straight post, two angles (10 and 20 degrees) to accommodate
divergent roots and a special Cast-to version. Plus five different retentive
males allow for your choice of regular retention (white),
strong angle correction (green), light retention (pink),
extra-light retention (blue), and light angle
correction (red) according to the needs of the patient.
Locator
Component Listing
9019 - LOCATOR IMPLANT SUPPORT
PACKAGE
LOCATOR Implant Support Package Special Price: $405.00
(Retail Value $505.00)
Includes:
- 9015 LOCATOR Implant Demo Model
- 8393 LOCATOR Core Tool
- 8519-2 LOCATOR Male Processing Package (2 Pack)
- 8505 LOCATOR Impression Coping (4 Pack)
- 8530 LOCATOR Analogs (4mm) (4 Pack)
- 8529 Extra Light Retention Males (Blue) (4 Pack)
- 8547 Extended Range Males (Green)(4 Pack)
- 8548 Extra Light Retention Extended Range Males (Red)(4Pack)
- 8517 Parallel Posts (4 Pack)
- 9530 Angle Measurement Guide
- 9018 LOCATOR Implant Technique Video
- 1 LOCATOR CD-Rom (Implant and Root
Techniques)
- 25 Patient Education Brochure
|
|
| |
|
9007 - LOCATOR ROOT SUPPORT PACKAGE
LOCATOR Root Support Package Special Price: $415.00
(Retail Value $565.00).
Includes:
- 9014 LOCATOR Root Demo Model
- 8393 LOCATOR Core Tool
- 8071 LOCATOR Mixed Kit
- 8516 LOCATOR Analogs (5mm) (4 Pack)
- 8529 Extra Light Retention Males (Blue) (4
Pack)
- 9017 LOCATOR Root Technique Video
- 1 LOCATOR CD-Rom (Implant and Root Techniques)
- 25 Patient Education Brochure
|
 |
| |
|
| 9015 - LOCATOR
MODEL - IMPLANT
(external hex)
Full lower
overdenture with two endosseous external hex implants and Locator implant attachments.
All DEMO models are sold at our manufacturing costs.
 |

|
| |
|
| 9006 - LOCATOR
MODEL - IMPLANT
(internal hex)
Full lower
overdenture with two endosseous internal hex implants and Locator implant attachments.
All DEMO models are sold at our manufacturing costs.
 |
|
| |
|
| 9014 - LOCATOR MODEL - ROOT
Full Lower Overdenture with Two Cuspids Roots with LOCATOR Root attachments.
All DEMO models are sold at our manufacturing costs.
|
|
| |
|
8393 - LOCATOR CORE TOOL
This 3-in-1 tool contains:
- The Male Removal Tool
- Male Seating Tool and
- Gold-Plated Implant Abutment Driver.
This tool is required for placement procedure of all Locator Root
Attachments and Locator Implant Abutments.
|

|
| |
|
8390 - LOCATOR Abutment Driver
The LOCATOR Abutment Driver is a special gold plated driver designed to engage the inside diameter of the Locator Abutment and thread it into the implant.
Please Note: A .050 (1.25mm) Hex Torque Wrench Driver Tip will fit into the backside of the LOCATOR Abutment Driver to help achieve the minimum seating force of 20N-cm.
 |
|
| |
|
8394 - LOCATOR Abutment Delivery Sleeve
The Locator Abutment Delivery Retaining Sleeve is designed for use with the #8390 driver/#8393 Core tool when taking an abutment to the mouth. Strongly reduces chance of abutment falling "out" of the driver tool.
Package of 4 and Package of 20.

|
|
| |
|
8397 - LOCATOR Male Removal Tool
The Male Removal Tool is used to remove the nylon male from the metal denture cap. The sharp circular edge of the removal tool should be wedged tightly down into the very bottom of the plastic male so that it will catch the inside of the plastic insert and pull it at an angle out of the metal housing. Prior to use, loosen the tip a full 3 turns counter clockwise (you will see a visible gap). To discard the nylon male from the tip of the Core Tool; point the tool down and away from you and tighten the Male Removal Tool clockwise back onto the Core Tool. This will activate the removal pin and dislodge the nylon male from the tip end.
|
|
| |
|
4391 -
LOCATOR TORQUE WRENCH
Tool kit is used for tightening LOCATOR abutments to the recommended torque of minimum 20 Newton Centimeters.
Kit contains: 20 Ncm Torque Wrench, LOCATOR Driver Insert (15mm) (8926), and Thumb Knob Wrench. All components are stainless steel and very easy to maintain and sterilize by either autoclave or chemclave.
|
 |
| |
|
9020 -
LOCATOR TORQUE WRENCH
Tool kit is used for tightening LOCATOR abutments to 30 Newton Centimeters.
Kit contains: 30Ncm Torque Wrench, 15mm Locator Insert Driver and a Thumb Knob Wrench. All components are stainless steel and very easy to maintain and sterilize by either autoclave or chemclave
|
 |
| |
|
| 8260 - LOCATOR 35NCM TORQUE WRENCH INSERT DRIVER (15MM)
For use with Straumann torque wrenches.

|
|
| |
|
8280 - LOCATOR 35NCM TORQUE WRENCH INSERT DRIVER (21MM)
For use with Straumann e torque wrenches.

|
|
| |
|
| 8913 - LOCATOR INSERT DRIVER (LATCH-TYPE CONNECTION)
23mm total length. This driver goes direct from a latch-type connection torque wrench to the LOCATOR Implant Abutment and allows direct torque tightening of the LOCATOR Implant Abutments.
Compatibles: 3i Implant Innovations, Nobel BioCare, and Thommen Medical.

|
|
| |
|
8914 - LOCATOR INSERT DRIVER (LATCH-TYPE CONNECTION)
29mm total length. This driver goes direct from a latch-type connection torque wrench to the LOCATOR Implant Abutment and allows direct torque tightening of the LOCATOR Implant Abutments.
Compatibles: 3i Implant Innovations, Nobel BioCare, and Thommen Medical.

|
|
| |
|
| 8926 - LOCATOR TORQUE WRENCH DRIVER (SQUARE DRIVE CONNECTION)
15mm total length. This driver goes direct from a square drive connection torque wrench to the LOCATOR Implant Abutment and allows direct torque (minimum 20 Ncm) tightening of the LOCATOR Implant Abutments.
Compatibles: Zest Anchors, Astra Tech, Bio-Horizon, Lifecore, Innova, and Zimmer.

|
|
| |
|
8927 - LOCATOR TORQUE WRENCH DRIVER (SQUARE DRIVE CONNECTION)
21mm total length. This driver goes direct from a latch drive connection torque wrench to the LOCATOR Implant Abutment and allows direct torque (minimum 20 Ncm) tightening of the LOCATOR Implant Abutments.
Compatibles: 3i Implant Innovations, Steri-Oss, and Thommen Medical.

|
|
| |
|
|
4936 - .050 (1.25MM) HEX INSERT DRIVER FOR TORQUE WRENCH
.050 Hex Driver (Square Drive Connection) for the Torque Wrench Kit.

|
|
| |
|
| 8924 - LOCATOR PILOT DRILL
6mm x 1.8mm Diameter with Plastic Depth Reference Ring.
For use with 8520, 8521, 8522, and 8528 Locator females
Also Order: Locator Spotface Diamond Bur
(8922).
|
|
| |
|
8922 - LOCATOR SPOTFACE DIAMOND
BUR
Countersink drill creates the minimal cementation surface possible on the root.
For use with 8520, 8521, 8522, and 8528 Locator females
Also Order: Locator Pilot Drill (8924).
|
|
| |
|
9102 - 1.7MM BAR DRILL
(2.0mm Thread)
1.7mm Bar Drill (2.0mm Thread) indicated for use with the LOCATOR Bar Female
(8589).
Also order: 2.0mm Bar Tap (9104).
|

|
| |
|
9104 - 2.0MM BAR TAP
2.0mm Bar Tap (2.0mm Thread) indicated for use with the LOCATOR Bar Female
(8589) and 1.7mm Bar Drill.
|

|
| |
|
9103 - LOCATOR 1.8MM BAR DRILL
(2-56 THREAD)
1.8mm Bar Drill (2-56Thread) indicated for use with the LOCATOR Bar Female
(8587).
Also order: 2-56 Bar Tap (2-56 Thread)(9105).

|

|
| |
|
9105 - 2-56 BAR TAP (2-56 THREAD)
2-56 Bar Tap indicated for use with the LOCATOR Bar Female (8587)(2-56
Thread) and 1.8mm Bar Drill (9103).
 |

|
| |
|
| 8014 - Threaded
Castable Sleeve (2.0MM)
2.0mm Delrin Castable Threaded Insert (10 pack) makes it even easier to create a threaded site in an implant bar for accepting the threaded LOCATOR Bar Female (8589).
Also Order: LOCATOR Bar Female (8589), 2.0mm Bar Tap (9104) and Drill & Tap Holder (8016). |

|

|
| |
|
| 8013 - Threaded
Castable Sleeve (2-56 THREAD)
2.0mm Delrin Castable Threaded Insert (10 pack) makes it even easier to create a threaded site in an implant bar for accepting the threaded LOCATOR Bar Female (8587).
Also Order: LOCATOR Bar Female (8587), 2-56mm Bar Tap (9105) and Drill & Tap Holder (8016).

|

|
| |
|
| 8016 - Drill
and Tap Holder
Made to fit into the handpiece of a milling unit in the dental laboratory, the tool has set screws for holding the LOCATOR Bar Drill and then the LOCATOR Bar Tap in place while performing an exact parallel preparation (which means less chance of breaking a tap).

|
|
| |
|
9107 - LOCATOR PARALLELING MANDREL
FOR BAR FEMALE
The LOCATOR Paralleling Mandrel is indicated for all Laser Bar Females
(8588 & 8590) and is used in a surveyor to place the Laser Bar Female
into position.
 |

|
| |
|
| 8517 - LOCATOR PARALLEL POST (4
pack)
LDPE (Black), Locator Parallel Post may be used as a handle when seating
female and to visualize parallel alignment of multiple attachments.
 |

|
| |
|
1747 - LOCATOR Retrofit Kit (2)
for Worn ERA Root Attachments
Includes 2 LOCATOR® Retrofit Females, 2 Parallel Posts, and 2 Weep Hole Alignment Pins.
Please order Locator males separately.
New Locator female and male only requires an additional 0.32mm of inter-occlusal space!

|
 |
| |
|
| 8520 - LOCATOR 0º
DEGREE FEMALE (2 pack) Extra-Radicular Design. Stainless Steel with TiN coating. Female root
attachment extends above the root plane 1.5mm. Diameter 4.0mm with contact
face 3.75mm and post extension 6.0mm x 1.8mm. Post
may be shortened in length to 3.0mm if desired.
Width of root surface must equal or exceed 4.0mm.
Save 10% and order 8520-10 (5 packs of 2) Metal
content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045
(max), S 0.030 (max), Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100
(max).
TiN Coating (Titanium Nitride):
Titanium/Argon/Nitrogen 99% pure |

|
| |
|
| 8521 - LOCATOR 10º
DEGREE FEMALE
(2 pack) Extra-Radicular Design. Root Angled Correction. Stainless Steel with TiN
coating. Diameter 4.0mm with contact face 3.75mm and post extension
6.0mm x 1.8mm. Post may be shortened in length to 3.0mm if desired.
Width of root surface must equal or exceed 4.0mm.
Save 10% and order 8521-10 (5 packs of 2)
Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P
0.045 (max), S 0.030 (max), Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N
0.100 (max). TiN Coating (Titanium
Nitride): Titanium/Argon/Nitrogen 99% pure
|

|
| |
|
| 8522 - LOCATOR 20º
DEGREE FEMALE
(2 pack) Extra-Radicular Design. Root Angled Correction. Stainless Steel with TiN
coating. Diameter 4.0mm with contact face 3.75mm and post extension 6.0mm x
1.8mm. Post may be shortened in length to 3.0mm if desired.
Width of root surface must equal or exceed 4.0mm.
Save 10% and order 8522-10 (5 packs of 2) Metal
content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045
(max), S 0.030 (max), Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100
(max). TiN Coating (Titanium Nitride):
Titanium/Argon/Nitrogen 99% pure
|

|
| |
|
| 8528 - LOCATOR CAST-TO FEMALE
(2 pack) Extra-Radicular Design. Stainless Steel with 3.Omm
↕ x 1.8mm
Ø post extension,
assembled with parallel post. Please refer to Locator Root Attachment System
Technique for instructions. Also available in Locator Coping Kit
(8051/8050).
IMPORTANT NOTE: Do not allow the casting
temperature to raise above 2000 F which will melt the stainless steel
female. Do not use a bur to remove investment, sandblasting with aluminum oxide,
or an acid pickling solution, can damage the internal socket of the female
attachment. Do NOT shorten the threaded retention post.
8922 and 8924 drills must be used.
Save 10% and order 8528-10 (5 packs of 2)
Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P
0.045 (max), S 0.030 (max), Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N
0.100 (max). |

|
| |
|
8586 - LOCATOR CAST-TO BAR FEMALE
(2 PACK)
Stainless Steel. Indicated for casting-to a LOCATOR Bar Female into a gold
alloy bar.
Also order: LOCATOR Paralleling Mandrel for Bar Female (9107).
IMPORTANT NOTE: Do not allow the casting
temperature to raise above 2000 F which will melt the stainless steel
female. Do not use a bur to remove
investment, sandblasting with aluminum oxide, or an acid pickling solution,
can damage the internal socket of the female attachment

Save 10% and order 8586-10 (5 packs of 2)
Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P
0.045 (max), S 0.030 (max), Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N
0.100 (max).
|

|
| |
|
8587 - LOCATOR BAR FEMALE (2-56
THREAD)(2 PACK)
Titanium alloy with TiN coating.
LOCATOR Bar Female designed in a special thread size to replace
worn out TSB Ball Attachments. The only requirement is a minimum bar
width of 4mm to upgrade with a LOCATOR.
Also order: 1.8mm Bar Drill (2-56 Thread)(9103) and 2-56 Bar Tap(2-56
Thread)(9105)
Save 10% and order 8587-10 (5 packs of 2) |

|
| |
|
8588 - LOCATOR LASER BAR FEMALE,
TITANIUM (2 PACK)
Titanium alloy with TiN coating. Indicated for use with milled titanium
bars.
Also order: Paralleling Mandrel (9107) and extra Block-Out Spacers (8514)
Save 10% and order 8588-10 (5 packs of 2) |
|
| |
|
8589 - LOCATOR BAR FEMALE (2.0MM
THREAD) (2 PACK)
Titanium alloy with TiN coating.
For total retrievability you can simply drill, tap, and thread the new
LOCATOR Bar Female into your completed implant bar.
Also Order: 1.7mm Bar Drill (2.0mm Thread)(9102) and 2.0mm Bar Tap (2.0mm
Thread)(9104). The 1.7mm Bar Drill and a 2.0mm Bar Tap are used for creating
the threaded site into either a titanium bar or cast alloy bar.
Save 10% and order 8589-10 (5 packs of 2) |

|
| |
|
8590 - LOCATOR LASER BAR FEMALE,
STAINLESS STEEL (2 PACK)
Stainless steel and indicated for laser welding to a cast gold alloy bar.
Also order: LOCATOR Paralleling Mandrel for Bar Female (9107) and extra
Block-Out Spacers (8514).
Save 10% and order 8590-10 (5 packs of 2) |

|
|
Locator Implant Abutment
Listing
Implant attachment for internal, external, and
non-hexed implants. Please follow the above link to order the
correct abutment.
|
 |
| |
|
| 8516 - LOCATOR FEMALE ANALOG (5MM
DIAMETER)(4 PACK)
Aluminum. Locator Root Analog. Also used with Straumann and wide platform implant systems.
Also Order: Locator Impression Coping (8505)
Save 10% and order 8516-20 (5 packs of 4)
|
|
| |
|
| 8505 - LOCATOR IMPRESSION COPING (4
PACK)
Aluminum Housing with Black Locator LDPE Male (6.1mm height). The Locator
Impression Coping is designed with minimum retention to be picked up with
the impression material in a tray.
For Reline Impression with a denture use Locator Denture Cap with Black
Processing Male for lower profile space requirement.
Also Order: Locator 5mm Diameter
Analog (8516) or Locator 4mm Diameter Analog (8530).
Save 10% and order 8505-20 (5 packs of 4)
|
|
| |
|
|
8530 - LOCATOR FEMALE ANALOG (4MM
DIAMETER)(4 PACK)
Aluminum. Locator Female Analog (4mm) for regular and narrow platform implant systems.
Also Order: Locator Impression Coping (8505)
Save 10% and order 8530-20 (5 packs of 4)
|
|
| |
|
8540 - LOCATOR EXTENDED RANGE MALE PROCESSING
PACKAGE (2 PACK) TI
Includes: Titanium Denture Cap with Black Processing Male, Red Male
(0.5-1.0lbs), Orange Male (2.0lbs), Green Retention Male
(3.5-4.0lbs), and Block-Out Spacer.
Save 10% and order 8540-10 (5 packs of 2)
|
|
| |
|
8519 - LOCATOR MALE PROCESSING
PACKAGE (2 PACK) TI
Includes: Titanium Denture Cap with Black Processing Male, White Nylon Male
(5lbs), Pink Medium Retention Nylon Male (3lbs),
Blue Light Retention Male
(1.5lbs), and Block-Out Spacer.
Save 10% and order 8519-10 (5 packs of 2)
|
|
| |
|
8550 - LOCATOR MALE PROCESSING
PACKAGE (2 PACK)
SS
Includes: Stainless Steel Denture Cap with Black Processing Male, White Nylon Male
(5lbs), Pink Medium Retention Nylon Male (3lbs), Blue Light Retention Male
(1.5lbs), and Block-Out Spacer.
Designed for laser welding to cast frameworks
Save 10% and order 8550-10 (5 packs of 2)
|
|
| |
|
| 8028 - LOCATOR
BAR PROCESSING
PACKAGE (2 PACK)
Includes: Denture Cap with Yellow Bar
Processing Male, White Nylon Male (5lbs), Pink Medium
Retention Nylon Male (3lbs),
Blue Light Retention Male
(1.5lbs), and Block-Out Spacer (4).
Save 10% and order 8028-10 (5 packs of 2) |
|
| |
|
8524 - LOCATOR REPLACEMENT MALE WHITE
WHITE (4 PACK) 5lbs
Strong Retention Replacement White Nylon Male (5lbs) used with LOCATOR Male Denture Cap.
Save 10% and order 8524-20 (5 packs of 4) |

|
| |
|
8527 - LOCATOR REPLACEMENT MALE PINK
PINK (4 PACK) 3lbs
Medium Retention Pink Nylon Replacement Male (3lbs) used with LOCATOR Male Denture Cap.
Save 10% and order 8527-20 (5 packs of 4) |
|
| |
|
| 8529 - LOCATOR
REPLACEMENT MALE BLUE
BLUE (4 PACK) 1.5lbs
Light Retention Blue Nylon Replacement Male (1.5lbs) used with LOCATOR Male Denture Cap.
.
Save 10% and order 8529-20 (5 packs of 4) |

|
| |
|
|
8547 - LOCATOR REPLACEMENT
MALE EXTENDED RANGE GREEN
GREEN (4 PACK) 3.5-4.0lbs
The Extended Range Replacement Male standard (green = 3.5-4lbs) can accommodate divergent abutments up to 20º (40º between multiple abutments)
Also Order: LOCATOR Male Processing Package
(8519-2) and LOCATOR Core Tool
Save 10% and order 8547-20 (5 packs of 4) |

|
| |
|
8915 - LOCATOR REPLACEMENT MALE EXTENDED RANGE ORANGE
ORANGE (4 PACK) 2.0LBS
The Extended Range Replacement Male light retention (orange = 2lbs) can accommodate divergent abutments up to 20º (40º between multiple abutments)
Also Order: LOCATOR Male Processing Package
(8519-2) and LOCATOR Core Tool
Save 10% and order 8915-20 (5 packs of 4)
|
|
| |
|
8548 - LOCATOR
REPLACEMENT MALE EXTENDED RANGE RED
RED (4 PACK)
0.5LBS
The Extended Range Replacement Male extra light (red = 0.5lbs) can accommodate divergent abutments up to 20º (40º between multiple abutments)
Also Order: LOCATOR Male Processing Package
(8519-2) and LOCATOR Core Tool
Save 10% and order 8548-20 (5 packs of 4) |
|
| |
|
8558 - LOCATOR REPLACEMENT MALE ZERO GRAY
GRAY(4 PACK) 0 LBS
The Extended Range Replacement Male ZERO can accommodate divergent abutments up to 20º (40º between multiple abutments)
Also Order: LOCATOR Male Processing Package
(8519-2) and LOCATOR Core Tool
Save 10% and order 8558-20 (5 packs of 4)
|
|
| |
|
8569 - LOCATOR PROCESSING SPACER (4 PACK)
Processing Male to be used by Laboratory when processing to create space in denture for chairside pickup.
Using the processing males eliminates the need for the dentist to relieve the denture when direct pickup of the males is indicated.
Save 10% and order 8569-20 (5 packs of 4)
|
|
| |
|
8515 - LOCATOR BLACK PROCESSING MALE (4 PACK)
Processing Black LDPE Male to be used with the Locator Denture Cap (8519) or Locator Impression Coping (8505) during relines, impressions, and direct processing of males
1-1.5 lbs of retention, but these
processing males do not provide any of the resiliency of the final Locator
males or last very long in the mouth.
Save 10% and order 8515-20 (5 packs of 4)
|

|
| |
|
| 8026 - LOCATOR
BAR YELLOW PROCESSING MALE (4 PACK)
Processing Yellow LDPE Male to be used with the Locator Denture Cap (8519) or Locator Impression Coping (8505) during relines, impressions, and direct processing of males
1-1.5 lbs of retention, but these
processing males do not provide any of the resiliency of the final Locator
males or last very long in the mouth
Save 10% and order 8026-20 (5 packs of 4)
|

|
| |
|
| 8514 - LOCATOR BLOCK OUT SPACER (20
PACK)
White Block-Out Spacer is placed over the Locator Root or Implant Abutment
and is used to block out the area immediately surrounding the abutment.
|

|
|