Repair and Servicing to Removable Partial Dentures Retained by Ceka AttachmentsDetermination of reline or rebase--Bilateral free end Prosthesis. Determine the need for a reline by placing fingers over the Ceka attachments and at the same time apply light pressure to the free-end saddle. If hinging is observed, a reline is necessary. Alternative Technique: Place 23 gauge soft wax (approximately .5mm) on the tissue bearing side of the saddles. Place the 694B (M3) or RE0096 (M2) spacer over the male spring pin. Seat the removable partial denture. Apply finger pressure directly over the attachments. Do NOT have the patient close and bite. Remove the prosthesis and inspect the 23 gauge soft wax.
Step One: Determining the correct size of Ceka Spring Pins View the patients records, or check the actual spring pin in the prosthesis, to determine whether the case was fabricated using the M3 or M2 spring pin (Ceka Spring Pin listing).
Removing/replacing a spring pin in the patients mouth:
Replacing a removable spring pin with broken segments:
In case of a small loss of retention, the head (bottom, or "cross hairs") of the spring pin may be slightly increased.
In case of larger losses of retention, use the Ceka Sizer to determine the appropriate spring pin for the existing female. Reasons for losses of retention are as follows:
Step Two: Impression Taking When parts are listed in the following sections, we will be referring to the M3 series. The M2 series has the same product number, only with a "RE" prefix (view Ceka components).
Create the male impression analogue by threading a spring pin, or (H1) working dummy pin, into the H14 using the A1 or REH5 tool. Using an incorrect tool (other than the A1 or H5) will spread the retention parts of the spring pin and not allow the male to seat in the female.
Step Three: Prepare the master model
A. Technique for Oversized Spring Pins
B. Oversized and Standard Spring Pin cases
Step Four: Process the Retention Cap into the Prosthesis The H1 (or the 694C and 694B) is unthreaded from the H14 in the impression. The H1 (or the 694C and 694B) is threaded into the retention cap of choice and is placed into the H13 on the master cast.
If a reline is being completed, process the reline over the retention cap to incorporate into the prosthesis. If a repair is being completed, please view the chairside procedure. Laboratory Procedure Remove all impression material from the immediate area of the Ceka male spring pins with a small Bard Parker blade. Place the 694B space maintainers over the Ceka male spring pins and snap the Ceka H13 accessory over each male spring pin. The opening on the side of Ceka H13 acts as a check point for the exact location of the male spring pin in the Ceka H13 accessory and should be blocked out with soft wax to prevent penetration of the plaster into the segments of the male spring pins. Cast the working model. For accurate relining, a reline jig or clamp is recommended. Mount the working model in the reline clamp using an occlusal plaster register or matrix. The teeth should be shallowly impressed (2mm to 3mm) in the plaster. The partial denture may now be removed to expose the tops of the Ceka H13 accessories which act as the Ceka females. These provide accurate horizontal and vertical location during processing. The impression material is now removed and sufficient acrylic resin is ground away from the base of the partial denture. The working model and substitute females now are painted with a separating medium. Replace the Ceka male spring pins with the correct Ceka dummy male spring pins--H1. Fill the metal sleeves in the framework surrounding the Ceka male spring pins with silicone rubber to prevent acrylic resin penetration. The metal frame should be prevented from moving during processing by fixing the major connector to the working model with a small amount of stone. Place a thin film of vaseline over the acrylic resin parts and artificial teeth to prevent any new acrylic resin from sticking to places where it is not required. Place the partial denture in the occlusal incisal register and pour the acrylic resin into place, then process under pressure. When set, remove the partial denture from the working model, being careful not to damage or break the working model. Finish and polish the partial denture. Finally, replace the Ceka dummy male spring pins (H1) with either the original or new Ceka male spring pins. The male spring pins should be threaded into the retention part with Ceka Bond to prevent it from unthreading. Reseating or Replacing of a Ceka AKS Retention Part in Acrylic Resin Chairside Procedure A Ceka male spring pin is threaded into an AKS retention part. The small 694B space maintainers coated with vaseline are positioned over the Ceka male spring pin. Snap the male spring pin into the Ceka female. Block out the area beneath Ceka female in the mouth. Remove sufficient acrylic resin from the partial denture to allow it to be accurately and fully seated underneath the Ceka retention part in the mouth without touching the Ceka attachment. It is always recommended that a small hole be cut on the lingual of the prosthesis as an escape vent for any excess self-curing resin. Seat the Ceka attachment with small space maintainers--694B--correctly in the partial denture in the patient's mouth and hold it in place with fingers while carefully self-curing the Ceka AKS retention part in the partial denture, using the brush liquid-powder technique. Do not have the patient bite, or come to full occlusion, as this can cause tissue compression in the posterior and thus attachment misalignment. After the self-cure resin is set, remove the partial denture and finish. Discard the spacer.
Laboratory Procedure (if necessary) Snap the H13 female analogue over the Ceka male spring pin. To avoid stone flowing between the segments of the male spring pin, fill the opening in the Ceka H13 female analogue and the sleeve of the metal frame around the Ceka attachment with silicone rubber. Use the small space maintainer (694B) with Ceka resilient attachments. Block out the undercuts of the saddles and pour a working model. Remove the Ceka AKS retention component and male spring pin from the partial denture. The retention part may then be re-attached using self cure resin. T-0001.REV.03
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||