|
|
Extracoronal Attachments
|
M2: 4.00mm vertical,
3.50mm Ø |
M3: 4.55mm vertical,
4.30mm
Ø |
|
 |
 |
Extracoronal
Ceka Revax
|
 |
|
M3: OL 285TI
Titanax female for bonding with Ceka Site.
Retention
part for the bonding technique, also with Ceka Site.
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
completed.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- Provides option to
veneer directly to the removable partial denture metal frame for improved
esthetics. The first tooth of the removable partial denture looks like a
tooth and blends with the abutment crowns.
- The Spacer
(bonding) retention system is very technique sensitive, and
the instructions must be thoroughly followed.
|
|
|
M2: RE 185TI
Reduced size
Titanax female for bonding with Ceka Site.
Retention
part for the bonding technique, also with Ceka Site.
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
completed.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- Provides option to
veneer directly to the removable partial denture metal frame for improved
esthetics. The first tooth of the removable partial denture looks like a
tooth and blends with the abutment crowns.
- The Spacer
(bonding) retention system is very technique sensitive, and
the instructions must be thoroughly followed.
|
|
|
M3: OL 261TI
Titanax female for bonding with Ceka Site.
Retention
part for soldering.
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
comleted.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- A strong
solder
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|
|
|
M2: RE 161TI
Reduced Size
Titanax female for bonding with Ceka Site.
Retention
part for soldering.
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
comleted.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- A strong
solder
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|
|
|
M3: OL 275TI
Titanax female for bonding with Ceka Site.
Retention
part for acrylic resin.
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
completed.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- The
acrylic retention cap
may be easily removed (use heat) from the prosthesis and replaced or
repositioned if necessary.
-
Clinical/Intra-oral: the acrylic retention cap is easily connected to a
cast frame in the mouth
-
Clinical/Intra-oral: the acrylic retention cap may be easily picked up in
the mouth
|
|
|
M2: RE 175TI
Reduced Size
Titanax female for bonding with Ceka Site.
Retention
part for acrylic resin.
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
completed.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- The
acrylic retention cap
may be easily removed (use heat) from the prosthesis and replaced or
repositioned if necessary.
-
Clinical/Intra-oral: the acrylic retention cap is easily connected to a
cast frame in the mouth
-
Clinical/Intra-oral: the acrylic retention cap may be easily picked up in
the mouth
|

 |
|
M3: OL 265TI
Titanax female for bonding with Ceka Site.
Titanium retention
part for laser welding.
Laser products
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
comleted.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- A strong
laser
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|


|
|
M2: RE 165TI
Reduced Size
Titanax female for bonding with Ceka Site.
Titanium retention
part for laser welding.
Laser products
Benefits:
- Casting may be in any alloy
- No miscast or devesting errors. The accurate
titanium female insert is bonded in after all other procedures are
comleted.
- The abutment crowns and female attachment may be
altered if necessary after try-in.
- A strong
laser
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|
|
|
M3: OL 285IR
Irax female for direct casting with precious and palladium
based alloys.
Retention part for the bonding technique.
Benefits:
- The red and blue systems provide the convenience of
directly casting the female with the abutment crown(s)
- Select the RED system
for casting precious or
semi-precious alloys
- Provides option to
veneer directly to the removable partial denture metal frame for improved
esthetics. The first tooth of the removable partial denture looks like a
tooth and blends with the abutment crowns.
- The Spacer
(bonding) retention system is very technique sensitive, and
the instructions must be thoroughly followed.
|
|
|
M2: RE 185IR
Reduced Size
Irax female for direct casting with precious and palladium
based alloys.
Retention part for the bonding technique.
Benefits:
- The red system provides the convenience of
directly casting the female with the abutment crown(s)
- Select the RED system
for casting precious or
semi-precious alloys
- Provides option to
veneer directly to the removable partial denture metal frame for improved
esthetics. The first tooth of the removable partial denture looks like a
tooth and blends with the abutment crowns.
- The Spacer
(bonding) retention system is very technique sensitive, and
the instructions must be thoroughly followed.
|
 |
|
M3: OL 261IR
Irax female for direct casting with precious and palladium
based alloys.
Retention part for soldering.
Benefits:
- The red and blue systems provide the convenience of
directly casting the female with the abutment crown(s)
- Select the RED system
for casting precious or
semi-precious alloys
- A strong
solder
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|
|
|
M2: RE 161IR
Reduced Size
Irax female for direct casting with precious and palladium
based alloys.
Retention part for soldering.
Benefits:
- The red and blue systems provide the convenience of
directly casting the female with the abutment crown(s)
- Select the RED system
for casting precious or
semi-precious alloys
- A strong
solder
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|
|
|
M3: OL 275IR
Irax female for direct casting with precious and palladium
based alloys.
Retention part for acrylic resin.
Benefits:
- The red and blue systems provide the convenience of
directly casting the female with the abutment crown(s)
- Select the RED system
for casting precious or
semi-precious alloys
- The
acrylic retention cap
may be easily removed (use heat) from the prosthesis and replaced or
repositioned if necessary.
-
Clinical/Intra-oral: the acrylic retention cap is easily connected to a
cast frame in the mouth
-
Clinical/Intra-oral: the acrylic retention cap may be easily picked up in
the mouth
|
|
|
M2: RE 175IR
Reduced Size
Irax female for direct casting with precious and palladium
based alloys.
Retention part for acrylic resin.
Benefits:
- The red and blue systems provide the convenience of
directly casting the female with the abutment crown(s)
- Select the RED system
for casting precious or
semi-precious alloys
- The
acrylic retention cap
may be easily removed (use heat) from the prosthesis and replaced or
repositioned if necessary.
-
Clinical/Intra-oral: the acrylic retention cap is easily connected to a
cast frame in the mouth
-
Clinical/Intra-oral: the acrylic retention cap may be easily picked up in
the mouth
|
 |
|
M3: OL 285NP
Noprax female for direct casting with only non-precious
alloys.
Retention part for the bonding technique.
Benefits:
- Select the BLUE system
for casting non-precious alloys
- Provides option to
veneer directly to the removable partial denture metal frame for improved
esthetics. The first tooth of the removable partial denture looks like a
tooth and blends with the abutment crowns.
- The Spacer
(bonding) retention system is very technique sensitive, and
the instructions must be thoroughly followed.
|
|
|
M2: RE 185NP
Reduced Size
Noprax female for direct casting with only non-precious
alloys.
Retention part for the bonding technique.
Benefits:
- Select the BLUE system
for casting non-precious alloys
- Provides option to
veneer directly to the removable partial denture metal frame for improved
esthetics. The first tooth of the removable partial denture looks like a
tooth and blends with the abutment crowns.
- The Spacer
(bonding) retention system is very technique sensitive, and
the instructions must be thoroughly followed.
|
|
|
M3: OL 261NP
Noprax female for direct casting with only non-precious
alloys.
Retention part for soldering.
Benefits:
- Select the BLUE system
for casting non-precious alloys.
- A strong
solder
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|
|
|
M2: RE 161NP
Reduced Size
Noprax female for direct casting with only non-precious
alloys.
Retention part for soldering.
Benefits:
- Select the BLUE system
for casting non-precious alloys.
- A strong
solder
connection to the cast metal frame is used when vertical space is limited,
or the patient exhibits a very strong bite.
|


|
|
M3: OL 275NP
Noprax female for direct casting with only non-precious
alloys.
Retention part for acrylic resin.
Benefits:
- Select the BLUE system
for casting non-precious alloys.
- The
acrylic retention cap
may be easily removed (use heat) from the prosthesis and replaced or
repositioned if necessary.
-
Clinical/Intra-oral: the acrylic retention cap is easily connected to a
cast frame in the mouth
-
Clinical/Intra-oral: the acrylic retention cap may be easily picked up in
the mouth
|
 |
|
M2: RE 175NP
Reduced Size
Noprax female for direct casting with only non-precious
alloys.
Retention part for acrylic resin.
Benefits:
- Select the BLUE system
for casting non-precious alloys.
- The
acrylic retention cap
may be easily removed (use heat) from the prosthesis and replaced or
repositioned if necessary.
-
Clinical/Intra-oral: the acrylic retention cap is easily connected to a
cast frame in the mouth
-
Clinical/Intra-oral: the acrylic retention cap may be easily picked up in
the mouth
|
 |
Other
Ceka Attachment Listings
|