M2: 4.00mm vertical, 3.50mm Ø

M3: 4.55mm vertical, 4.30mm Ø

Extracoronal

Ceka Revax

 

 

M3: OL 285TI

Titanax female for bonding with Ceka Site. 

Retention part for the bonding technique, also with Ceka Site.

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics.  The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

 

 

 

M2: RE 185TI

Reduced size

Titanax female for bonding with Ceka Site. 

Retention part for the bonding technique, also with Ceka Site.

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics.  The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

 

M3: OL 261TI

Titanax female for bonding with Ceka Site. 

Retention part for soldering.

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are comleted.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

 

M2: RE 161TI

Reduced Size

Titanax female for bonding with Ceka Site. 

Retention part for soldering.

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are comleted.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

M3: OL 275TI

Titanax female for bonding with Ceka Site. 

Retention part for acrylic resin.

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

 

 

 

 

 

 

M2: RE 175TI

Reduced Size

Titanax female for bonding with Ceka Site. 

Retention part for acrylic resin.

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

 

 

 

M3: OL 265TI

Titanax female for bonding with Ceka Site. 

Titanium retention part for laser welding.

Laser products

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are comleted.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • A strong laser connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

   

    

 

 

 

 

M2: RE 165TI

Reduced Size

Titanax female for bonding with Ceka Site. 

Titanium retention part for laser welding.

Laser products

Benefits:

  • Casting may be in any alloy
  • No miscast or devesting errors.  The accurate titanium female insert is bonded in after all other procedures are comleted.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • A strong laser connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

                                     

 

 

M3: OL 285IR

Irax female for direct casting with precious and palladium based alloys.

Retention part for the bonding technique.

Benefits:

  • The red and blue systems provide the convenience of directly casting the female with the abutment crown(s)
  • Select the RED system for casting precious or semi-precious alloys
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics.  The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

 

 

 

M2: RE 185IR

Reduced Size

Irax female for direct casting with precious and palladium based alloys.

Retention part for the bonding technique.

Benefits:

  • The red system provides the convenience of directly casting the female with the abutment crown(s)
  • Select the RED system for casting precious or semi-precious alloys
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics.  The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

 

M3: OL 261IR

Irax female for direct casting with precious and palladium based alloys.

Retention part for soldering.

Benefits:

  • The red and blue systems provide the convenience of directly casting the female with the abutment crown(s)
  • Select the RED system for casting precious or semi-precious alloys
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

 

 

 

M2: RE 161IR

Reduced Size

Irax female for direct casting with precious and palladium based alloys.

Retention part for soldering.

Benefits:

  • The red and blue systems provide the convenience of directly casting the female with the abutment crown(s)
  • Select the RED system for casting precious or semi-precious alloys
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

 

 

M3: OL 275IR

Irax female for direct casting with precious and palladium based alloys.

Retention part for acrylic resin.

Benefits:

  • The red and blue systems provide the convenience of directly casting the female with the abutment crown(s)
  • Select the RED system for casting precious or semi-precious alloys
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

 

 

 

 

M2: RE 175IR

Reduced Size

Irax female for direct casting with precious and palladium based alloys.

Retention part for acrylic resin.

Benefits:

  • The red and blue systems provide the convenience of directly casting the female with the abutment crown(s)
  • Select the RED system for casting precious or semi-precious alloys
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

 

 

M3: OL 285NP

Noprax female for direct casting with only non-precious alloys.

Retention part for the bonding technique.

Benefits:

  • Select the BLUE system for casting non-precious alloys
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics.  The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

 

 

 

 

 

M2: RE 185NP

Reduced Size

Noprax female for direct casting with only non-precious alloys.

Retention part for the bonding technique.

Benefits:

  • Select the BLUE system for casting non-precious alloys
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics.  The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

 

 

 

 

M3: OL 261NP

Noprax female for direct casting with only non-precious alloys.

Retention part for soldering.

Benefits:

  • Select the BLUE system for casting non-precious alloys.
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

 

 

 

 

M2: RE 161NP

Reduced Size

Noprax female for direct casting with only non-precious alloys.

Retention part for soldering.

Benefits:

  • Select the BLUE system for casting non-precious alloys.
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

 

 

 

 

 

 

M3: OL 275NP

Noprax female for direct casting with only non-precious alloys.

Retention part for acrylic resin.

Benefits:

  • Select the BLUE system for casting non-precious alloys.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

 

 

M2: RE 175NP

Reduced Size

Noprax female for direct casting with only non-precious alloys.

Retention part for acrylic resin.

Benefits:

  • Select the BLUE system for casting non-precious alloys.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

 

 

 